0

GEO5

Контекстная справка

Tree
Settings
Программа:
Язык

Design of Longitudinal Reinforcement for Slabs

The design of reinforcement is performed for load caused by the bending moment Md. The program provides the required area of tensile and compressive (if needed) reinforcement. It takes into account conditions for the minimum and maximum degree of reinforcement in a given cross-section. First, the program determines the location of neutral axis as:

Providing the location of neutral axis is less than the allowable one (x < xmax), the program determines the area of tensile reinforcement Ast from the expression:

Providing the location of neutral axis is greater than the allowable one (x > xmax), the program determines the areas of both compressive Asc and tensile Ast reinforcement from the expressions:

The limit location of neutral axis is found from:

The computed degree of reinforcement is checked using the following expressions:

where:

- for  fy = 460 N/mm2

- for  fy = 250 N/mm2

If the maximum degree of reinforcement ρmax is exceeded, the program informs the user that the longitudinal reinforcement cannot be designed for a given cross-section.

The program verifies a reinforced concrete pile using the method of limit deformation. The maximum allowable strain of concrete in compression is 0,002 - 0,0035.

The degree of reinforcement is checked using the formula:

  • Column - check for dominant compression

ρmax = 0,04

ρmin = 0,0013

- for  fy = 460 N/mm2

ρmin = 0,0024

- for  fy = 250 N/mm2

  • Beam - check for dominant bending

ρmax = 0,06

ρmin = 0,004

where:

d

-

pile diameter

As

-

reinforcement area

Interaction diagram N-M

Usage ratio of concrete cross-section subject to the combination of bending moment and normal force is determined as |0L| / |0R|. Where L is load and R is strength with prescribed eccentricity.

Скачайте бесплатную демо-версию GEO5.